Question
Rafael –
If my Chimney pipe need to be 15 inches taller than the roof (so that it matches the height of the tallest point within 10ft), does this roof vent/chimney cap count toward that height, or does that height need to be reached independently of the chimney cap.
Upvote if this was helpful (0) Downvote if this was not helpful (0) Watch Unwatch Flag for removal
Cody Hennigan (verified owner) –
Rafeal-
According to the 3-2-10 rule, the chimney opening needs to be 3′ above the roof penetration/edge of the roof depending on if its a roof exit or wall exit, or 2′ above any part of the structure within 10′, whichever is higher.
The roof vent is not included in this calculation because the vent itself is open so technically the flue terminates at the base of the vent, not the top.
Email us at support@tinywoodstove.com with any further questions!