Dwarf Heat Shield

$175.00$195.00

The Dwarf Heat Shield kit reduces clearances by 50% from the back and sides of your Dwarf Stove.  This easy-to-install kit attaches directly to the accessory mounting points on the Dwarf 3kW Standard, Dwarf 4kW, or Dwarf 5kW wood stove.

Note: The Dwarf Heat Shield Kit reduces the required clearances from the sides and back of the stove ONLY. If you are using single-wall pipe, you may need some additional shielding for the pipe in order to safely use the minimum clearances around the stove. Check out the Pipe Heat Shields here and see our article on How to Build Heat Shields for options to reduce clearances around stovepipe.

SKU: heatshield Category:

Three-piece heat shield constructed of 11 and 18 gauge steel and coated with high temp black powder coating.  Reduces required clearances to 8″ from the sides and 9″ from the back of the stove body.  Made in USA.

The shield stands 1″ away from the sides and back of the stove.  Clearances are measured from the stove body (behind the shield) to the nearest combustible material in all directions.

Includes three panels (left, right, and rear) with mounting brackets, required hardware, and an allen wrench.  Stove sold separately.

Installation instructions.

 

Compatibility

Works with the Direct Air kit, Tall Legs, and Wood Storage Stand accessories. When installing the Stove Heat Shield in conjunction with the Direct Air Intake kit, you may need to loosen the direct air a bit to slip the heat shield into place between the stove and direct air box.

Does not work with the rear exit option unless you cut a hole in the shield. Be aware that if your stove pipe extends beyond the heat shield, you’ll need to shield the pipe as well.

Does not work with the Dwarf 3kW LITE or legacy Dwarf models unless you drill your own mounting holes in the stove body.  If you’re not sure which model you have, check the left or right side of the stove for the four allen head accessory mounting screws.  If there are none, you’ll need to drill your own holes.

 

⚠ Warning: California Proposition 65

Use of this product can expose you to chemicals including soot, creosote, wood dust, and wood smoke containing carbon monoxide, which are known to the State of California to cause cancer, birth defects, or other reproductive harm.  For more information, visit www.P65Warnings.ca.gov.

 

Share your thoughts!

Let us know what you think...

What others are saying

  1. Question

    Amy

    Will you have an option for rear exit flues? Unfortunately I am unable to use the top of the stove exit for my flue.

    Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

    Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

    • Dan

      Dan

      Amy-

      Good question! This kit is designed to use the top exit out of the box, but you do have some options if you want to use a rear exit.

      To use a rear exit with the current heat shield, you can cut a hole in the rear of the shield for the pipe to pass through. If you do that, you may want to use an insulated tee as your rear exit instead of the standard single-wall rear exit kit. The clearances required for the single-wall rear exit kit would likely negate the benefit of using the heat shield kit unless you added additional shielding around the pipe.

      Alternatively, if you want to use the heat shield kit on just the sides of the stove and not use it on the back, you can just assemble the kit without adding the rear panel. That would leave the rear of the stove clear to accept a rear exit kit. Again, you’d want to be mindful of the clearances required around the pipe and the rear of the stove, and you may need to add some custom shielding to the pipe.

      Depending on the level of interest, we may add some additional products in the future like pre-fabricated heat shields for pipes, as well as a different rear panel for the heat shield kit to use with a rear exit. However, it may be some time before those are available. In the meantime, cutting single-wall pipe in the next size up works great for making pipe-mounted shields.

      Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

      Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

    • Lynn

      Can you install only the rear heat shield not the sides?

      Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

      Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

    • Dan

      Dan

      Amy-

      Good question. The way that Dwarf Heat Shield Kit is designed, the side shields attach to the sides of the stove, and then the back panel attaches to the side panels. So there’s no straightforward way of installing the rear panel without the side panels.

      That’s not to say that an attached heat shield couldn’t be mounted to the rear, only that the Dwarf Heat Shield Kit does not do that out of the box. Others have made custom rear-attached shields with success using off-the-shelf 24 gauge (or thicker) steel. There are available mounting points on the rear of the stove (threaded M6 1.0) that you could use if you wanted to build a custom shield.

      Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

      Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

  2. Question

    Carl Raymond

    Is the heat shield kit include three shields or one plus hardware?

    Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

    Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

    • Dan

      Dan

      Carl-

      Thanks for the question! The Dwarf Heat Shield kit includes three panels (left side, right side, and back), and all the hardware required to install it on the stove it’s designed for (current generation Dwarf 3kW Standard, Dwarf 4kW, or Dwarf 5kW).

      Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

      Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

  3. Question

    kevin

    Does it work with The Dwarf 3kw LITE?

    Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

    Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

    • Dan

      Dan

      Thanks for the question, Kevin. The Dwarf 3kW LITE is the same size and output as the Dwarf 3kW Standard, so the heat shield is the right size and would be equally effective. But the 3kW LITE does not come with accessory mounting points like the 3kW Standard does. So if you want to install a heat shield on your 3kW LITE, you’ll need to drill/tap some holes in the stove body to mount it.

      Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

      Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

  4. Question

    Ryan (verified owner)

    When the attached heat shield reduces the required clearances by 50% will adding additional types (air, fiber cement, insulated) of shields further reduce the clearance requirements? i.e. would this shield and an air cooled heat shield properly installed on a wall reduce the clearance by 2/3 of 50%?

    Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

    Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

    • Elizabeth

      Elizabeth

      Ryan, this is a common question, especially from folks with very tight spaces. While logically it makes sense that the heat would be even better dispersed by combining two heat shields, the NFPA doesn’t provide any guidelines or testing data on the protection that can be achieved by combining heat shields. We haven’t done any independent testing either so I’d recommend sticking with the required clearances for an individual heat shield.

      Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

      Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

  5. Question

    Jo Ann Harris

    Do the heat shields create air movement around the stove? Whereby, the area between the stove and plates becomes heated and rises; sucking cooler air from the bottom of the plate and warmer air rising from the top of the plate? And would this constantly moving air past the body of the stove cool the stove? Or am I just understanding what the purpose of the shields are and not just a protector from the hot stove?

    Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

    Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

    • Cody Hennigan

      Cody Hennigan

      Jo Ann-
      Thanks for the message! Yes, the heat shields mounted to either the wall or stove create a convection of air that lowers the temperatures the nearby combustibles are exposed to. The stove-mounted heat shields don’t reduce the temperature of the stove itself but the heat shields will be a lower temp than the stove thus the combustibles are exposed to a lower temp metal. Does that make sense? Feel free to email us at support@tinywoodstove.com if you have further questions.

      Upvote if this was helpful (0) Downvote if this was not helpful (0) Flag for removal

      Something wrong with this post? Thanks for letting us know. If you can point us in the right direction...

×